型號.名稱Type and Designation
| 型號 Type |
名稱 Designation |
U UY MY |
天然丁苯橡皮絕緣(阻燃)氯丁橡皮護套礦用移動橡套軟電纜 NR/SBR rubber insulated Flame retardant grade neoprene(CR) rubber sheathed flexible cables forming purposes. |
UP UY P MYP |
天然丁苯橡皮絕緣(阻燃)氯丁橡皮護套礦用屏蔽移動橡套軟電纜 NR/SBR rubber insulated Flame retardant grade neoprene(CR) rubber sheathed flexible shielding cables forming purposes. |
UC MC |
天然丁苯橡皮絕緣(阻燃)氯丁橡皮護套采煤機軟電纜 NR/SBR rubber insulated Flame retardant grade neoprene(CR) rubber sheathed flexible coal cutter cables forming purposes. |
UCP MCP UCPQ |
天然丁苯橡皮絕緣(阻燃)氯丁橡皮護套采煤屏蔽軟電纜 NR/SBR rubber insulated Flame retardant grade neoprene(CR) rubber sheathed flexible coal cutter shielding cables forming purposes. |
UZ UZP MZ MZP |
天然丁苯橡皮絕緣(阻燃)氯丁橡皮護套礦用電鉆電纜 NR/SBR rubber insulated Flame retardant grade neoprene(CR) rubber sheathed flexible drill cables forming purposes. |
UYQ MYQ |
天然丁苯橡皮絕緣(阻燃)氯丁橡皮護套礦用輕型軟電纜 NR/SBR rubber insulated Flame retardant grade neoprene(CR) rubber sheathed flexible light-duty cables forming purposes. | |
生產范圍 Production range of cable
| 型號 Type |
額定電壓 Rated voltages V |
芯數 NO.of cores |
標稱截面 Nominal cross-sectional area mm2 |
| 主線 Principal line |
地線 Ground wire |
控制線 Controlled line |
| U* |
1000 |
3 |
1 |
1 |
2.5~70 |
| UP* |
1000 |
3 |
1 |
1 |
2.5~70 |
UY ● MY |
380/660 |
3 |
1 |
— |
4~70 |
UYP ● MYP |
380/660 |
3 |
1 |
— |
4~70 |
UYP ● MYP |
660/1140 |
3 |
1 |
— |
4~70 |
| UC* |
1000 |
3 |
1 |
2~7 |
10~50 |
UC ● MC |
380/660 |
3 |
1 |
3~7 |
16~50 |
| UCP* |
1000 |
3 |
1 |
2~7 |
10~50 |
UCP ● MCP |
380/660 |
3 |
1 |
3~7 |
16~50 |
| UCPQ* |
1140 |
3 |
1 |
3 |
35~70 |
UCP ● MCP |
660/1140 |
3 |
1 |
3 |
35~95 |
UZ ● UZP ● MZ MZP |
300/500 |
3 |
1 |
1 |
2.5~4 |
UYQ ● MYQ |
300/500 |
2~12 |
— |
— |
1.0~2.5 | |
注:“●”的產品按GB12792-1991標準生產。 “*”的產品按Q/320282DCE037-2003標準生產。 其余產品按MT818-1999標準生產。 Note: “●”indicates that the product is manufactured according to the standard of GB12972-1991 “*”indicates that the product is manufactured according to the standard of Q/320282DCE037-2003. The rest product is manufactured according to the standard of MT818-1999.
結構尺寸及主要技術參數Construction and main technical data ● 礦用移動橡套軟電纜 Flexible rubber-sheathed cables for mining purposes 型號(Type):U 額定電壓(Rating Voltage):1000V |
 |
 |
備注: 1、電纜絕緣主線芯之間及主線芯與地線之間的絕緣電阻,換算到+20℃時不低于100MΩ·km。 2、產品標準:Q/320282DCE037-2003。 3、U型電纜有4芯和5芯兩種結構,有3根主線芯和一根地線芯組成(5芯電纜中有一芯為控制線),圍繞墊芯絞合成纜,外面擠包氯化聚乙烯橡皮護套或黑色氯丁橡皮護套。 4、導電線芯:采用軟銅線,其性能符合 GB/T3956-1997。 5、絕緣:采用GB7594.2-1987中XJ-00A型橡皮。 6、線芯識別:采用絕緣分色識別,主線芯紅、綠、白。地線黑色,控制線白色。 7、成纜:主線芯、地線、控制線圍繞橡皮墊芯按右向絞合成纜。 8、護套:采用GB7594.7-1987中XH-03A型橡皮。 9、普通型U型成品電纜具有不延燃性能,阻燃型U型成品電纜的阻燃性能滿足MT386-1995的要求。 10、電纜標志:電纜表面印有型號、電壓、規格及制造廠名稱。 |
結構尺寸及主要技術參數Construction and main technical data ● 礦用移動橡套軟電纜 Flexible rubber-sheathed cables for mining purposes 型號(Type):MY 額定電壓(Rating Voltage):380/660V
| 芯數截面 Nom.cross sectional areas mm2 |
導體結構 Conductor structure NO./mm |
絕緣厚度 Insulation thickness mm |
護套厚度 Sheath thickness mm |
電纜外徑 Average diameter |
參考重量 Cable approx. weight kg/km |
導體(銅)***大直流電阻 Max.D.C. resistance(20 ℃ ) Ω /km |
20 ℃載流量 Current carring capacity(20 ℃ ) A |
| 標稱 Normianal mm |
***大 Max mm |
| 3 × 4+1 × 4 |
56/0.30 |
1.4 |
3.5 |
20.9 |
23.0 |
637 |
4.950 |
35 |
| 56/0.30 |
4.950 |
| 3 × 6+1 × 6 |
84/0.30 |
1.4 |
3.5 |
22.9 |
25.1 |
856 |
3.300 |
46 |
| 84/0.30 |
3.300 |
| 3 × 10+1 × 10 |
84/0.40 |
1.6 |
4.0 |
27.8 |
30.6 |
1304 |
1.910 |
64 |
| 84/0.40 |
1.910 |
| 3 × 16+1 × 10 |
126/0.40 |
1.6 |
4.0 |
30.3 |
33.3 |
1545 |
1.210 |
85 |
| 84/0.40 |
1.910 |
| 3 × 25+1 × 16 |
196/0.40 |
1.8 |
4.5 |
36.4 |
40.1 |
2269 |
0.780 |
113 |
| 126/0.40 |
1.210 |
| 3 × 35+1 × 16 |
276/0.40 |
1.8 |
4.5 |
40.5 |
44.6 |
2786 |
0.554 |
138 |
| 126/0.40 |
1.210 |
| 3 × 50+1 × 16 |
396/0.40 |
2.0 |
5.0 |
45.5 |
50.1 |
3554 |
0.386 |
173 |
| 126/0.40 |
1.210 |
| 3 × 70+1 × 25 |
360/0.50 |
2.0 |
5.0 |
51.5 |
55.1 |
4587 |
0.272 |
215 |
| 196/0.40 |
0.780 | |
 |
備注: 1、電纜絕緣主線芯之間及主線芯與地線之間的絕緣電阻,換算到+20℃時不低于100MΩ·km。 2、產品標準:MT818.5-1999。 3、MT型電纜有4芯和5芯兩種結構,有3根主線芯和一根地線芯組成(5芯電纜中有一芯為控制線),圍繞墊芯絞合成纜,外面擠包氯化聚乙烯橡皮護套或黑色氯丁橡皮護套。 4、導電線芯:采用軟銅線,其性能符合 GB/T3956-1997。 5、絕緣:采用GB7594.2-1987中XJ-00A型橡皮。 6、線芯識別:采用絕緣分色識別,主線芯紅、綠、白。地線黑色。 7、成纜:主線芯、地線、圍繞橡皮墊芯按右向絞合成纜。 8、護套:采用GB7594.7-1987中XH-03A型橡皮。護套橡皮的氧指數≥40。 9、成品電纜的阻燃性能滿足MT386-1995的要求。 10、電纜標志:電纜表面印有型號、電壓、規格及制造廠名稱。 |
結構尺寸及主要技術參數Construction and main technical data ● 礦用移動橡套軟電纜 Flexible rubber-sheathed cables for mining purposes 型號(Type):UY 額定電壓(Rating Voltage):380/660V
芯數截面 Nom.cross sectional areas mm2 |
導體結構 Conductor structure NO./mm |
絕緣厚度 Insulation thickness mm |
護套厚度 Sheath thickness mm |
電纜外徑 Average diameter |
參考重量 Cable approx. weight kg/km |
導體(銅)***大直流電阻 Max.D.C. resistance(20 ℃ ) Ω /km |
20 ℃載流量 Current carring capacity(20 ℃ ) A |
標稱 Normianal mm |
***大 Max mm |
| 3 × 4+1 × 4 |
56/0.30 |
1.4 |
3.5 |
20.3 |
23.4 |
637 |
4.950 |
35 |
| 56/0.30 |
4.950 |
| 3 × 6+1 × 6 |
84/0.30 |
1.4 |
3.5 |
23.0 |
26.4 |
856 |
3.300 |
46 |
| 84/0.30 |
3.300 |
| 3 × 10+1 × 10 |
84/0.40 |
1.6 |
4.0 |
27.5 |
31.3 |
1304 |
1.910 |
64 |
| 84/0.40 |
1.910 |
| 3 × 16+1 × 10 |
126/0.40 |
1.6 |
4.0 |
29.6 |
33.4 |
1545 |
1.210 |
85 |
| 84/0.40 |
1.910 |
| 3 × 25+1 × 16 |
196/0.40 |
1.8 |
4.5 |
35.6 |
39.8 |
2269 |
0.780 |
113 |
| 126/0.40 |
1.210 |
| 3 × 35+1 × 16 |
276/0.40 |
1.8 |
4.5 |
38.7 |
42.9 |
2786 |
0.554 |
138 |
| 126/0.40 |
1.210 |
| 3 × 50+1 × 16 |
396/0.40 |
2.0 |
5.0 |
43.6 |
47.9 |
3554 |
0.386 |
173 |
| 126/0.40 |
1.210 |
| 3 × 70+1 × 25 |
360/0.50 |
2.0 |
5.0 |
49.7 |
54.4 |
4587 |
0.272 |
215 |
| 196/0.40 |
0.780 | |
 |
備注: 1、電纜絕緣主線芯之間及主線芯與地線之間的絕緣電阻,換算到+20℃時不低于100MΩ·km。 2、產品標準:GB12972.5-1991。 3、UY型電纜是有3根主線芯和一根地線芯組成圍繞墊芯絞合成纜,外面擠包氯化聚乙烯橡皮護套或黑色氯丁橡皮護套。 4、導電線芯:采用軟銅線,其性能符合 GB/T3956-1997。 5、絕緣:采用GB7594.2-1987中XJ-00A型橡皮。 6、線芯識別:采用絕緣分色識別,主線芯紅、綠、白、地線黑色。 7、成纜:主線芯、地線、圍繞橡皮墊芯按右向絞合成纜。 8、護套:采用GB7594.7-1987中XH-03A型橡皮。 9、普通型UY型成品電纜具有不延燃性能,阻燃型UY型成品電纜的阻燃性能滿足MT386-1995的要求。 10、電纜標志:電纜表面印有型號、電壓、規格及制造廠名稱。 |
結構尺寸及主要技術參數Construction and main technical data ● 礦用移動屏蔽橡套軟電纜 Flexible shielding rubber-sheathed cables for mining purposes 型號(Type):UP 額定電壓(Rating Voltage):1000V
芯數截面 Nom.cross sectional areas mm2 |
導體結構 Conductor structure NO./mm |
絕緣厚度 Insulation thickness mm |
護套厚度 Sheath thickness mm |
電纜外徑 Average diameter |
參考重量 Cable approx. weight kg/km |
導體(銅)***大直流電阻 Max.D.C. resistance(20 ℃ ) Ω /km |
20 ℃載流量 Current carring capacity(20 ℃ ) A |
標稱 Normianal mm |
***大 Max mm |
| 3 × 4+1 × 4 |
56/0.30 |
1.4 |
3.5 |
23.7 |
26.1 |
730 |
4.950 |
35 |
| 56/0.30 |
1.4 |
4.950 |
| 3 × 4+1 × 4+1 × 4 |
56/0.30 |
1.4 |
3.5 |
26.7 |
29.4 |
825 |
4.950 |
35 |
| 56/0.30 |
1.4 |
4.950 |
| 56/0.30 |
1.4 |
4.950 |
| 3 × 6+1 × 6 |
84/0.30 |
1.4 |
3.5 |
25.2 |
27.7 |
959 |
3.300 |
46 |
| 84/0.30 |
1.4 |
3.300 |
| 3 × 10+1 × 6 |
84/0.40 |
1.6 |
4.0 |
29.6 |
32.6 |
1344 |
1.910 |
64 |
| 84/0.30 |
1.6 |
3.300 |
| 3 × 16+1 × 6 |
126/0.40 |
1.6 |
4.0 |
32.6 |
35.9 |
1593 |
1.210 |
85 |
| 84/0.30 |
1.6 |
3.300 |
| 3 × 25+1 × 10 |
196/0.40 |
1.8 |
4.5 |
38.0 |
41.0 |
2332 |
0.780 |
113 |
| 84/0.40 |
2.5 |
1.910 |
| 3 × 35+1 × 10 |
276/0.40 |
1.8 |
4.5 |
41.5 |
44.8 |
2864 |
0.554 |
138 |
| 84/0.40 |
2.5 |
1.910 |
| 3 × 50+1 × 10 |
396/0.40 |
2.0 |
5.0 |
46.5 |
49.8 |
3652 |
0.386 |
173 |
| 84/0.40 |
2.5 |
1.910 |
| 3 × 70+1 × 16 |
360/0.50 |
2.0 |
5.0 |
51.5 |
55.1 |
4689 |
0.272 |
215 |
| 126/0.40 |
2.9 |
1.210 | |
 |
備注: 1、電纜絕緣主線芯之間及主線芯與地線之間的絕緣電阻,換算到+20℃時不低于100MΩ·km。 2、主線芯屏蔽層的過渡電阻換算到20℃時不高于3kΩ。 3、產品標準:Q/320282DCE037-2003。 4、UP型電纜有4芯和5芯兩種結構,有3根主線芯和一根地線芯組成(5芯電纜中有一芯為控制線),圍繞墊芯絞合成纜,外面擠包黑色氯化聚乙烯橡皮護套或黑色氯丁橡皮護套。 5、導電線芯:采用軟銅線,其性能符合 GB/T3956-1997。 6、絕緣:采用GB7594.2-1987中XJ-00A型橡皮。 7、線芯識別:采用絕緣分色識別,主線芯紅、綠、白。地線黑色,控制線白色。 8、地線:采用半導電橡皮包覆。 9、絕緣屏蔽:在絕緣表面包半導電帶。 10、成纜:主線芯、地線、控制線圍繞半導電橡皮墊芯按右向絞合成纜。 11、護套:采用GB7594.7-1987中XH-03A型橡皮。 12、普通型UP型成品電纜具有不延燃性能,阻燃型UP型成品電纜的阻燃性能滿足MT386-1995的要求。 13、電纜標志:電纜表面印有型號、電壓、規格及制造廠名稱。 |
結構尺寸及主要技術參數Construction and main technical data ● 礦用移動屏蔽橡套軟電纜 Flexible shielding rubber-sheathed cables for mining purposes 型號(Type):MYP 額定電壓(Rating Voltage):380/660V
芯數截面 Nom.cross sectional areas mm2 |
導體結構 Conductor structure NO./mm |
絕緣厚度 Insulation thickness mm |
護套厚度 Sheath thickness mm |
電纜外徑 Average diameter |
參考重量 Cable approx. weight kg/km |
導體(銅)***大直流電阻 Max.D.C. resistance(20 ℃ ) Ω /km |
20 ℃載流量 Current carring capacity(20 ℃ ) A |
標稱 Normianal mm |
***大 Max mm |
| 3 × 4+1 × 4 |
56/0.30 |
1.4 |
3.5 |
22.9 |
25.2 |
730 |
4.950 |
35 |
| 56/0.30 |
4.950 |
| 3 × 6+1 × 6 |
84/0.30 |
1.4 |
3.5 |
24.7 |
27.2 |
959 |
3.300 |
46 |
| 84/0.30 |
3.300 |
| 3 × 10+1 × 10 |
84/0.40 |
1.6 |
4.0 |
29.7 |
32.7 |
1427 |
1.910 |
64 |
| 84/0.40 |
1.910 |
| 3 × 16+1 × 10 |
126/0.40 |
1.6 |
4.0 |
32.2 |
35.4 |
1675 |
1.210 |
85 |
| 84/0.40 |
1.910 |
| 3 × 25+1 × 16 |
196/0.40 |
1.8 |
4.5 |
38.3 |
41.0 |
2419 |
0.780 |
113 |
| 126/0.40 |
1.210 |
| 3 × 35+1 × 16 |
276/0.40 |
1.8 |
4.5 |
42.4 |
46.6 |
2952 |
0.554 |
138 |
| 126/0.40 |
1.210 |
| 3 × 50+1 × 16 |
396/0.40 |
2.0 |
5.0 |
47.4 |
51.0 |
3741 |
0.386 |
173 |
| 126/0.40 |
1.210 |
| 3 × 70+1 × 25 |
360/0.50 |
2.0 |
5.0 |
52.4 |
57.1 |
4790 |
0.272 |
215 |
| 196/0.40 |
0.780 | |
 |
備注: 1、電纜絕緣主線芯之間及主線芯與地線之間的絕緣電阻,換算到+20℃時不低于100MΩ·km。 2、主線芯屏蔽層的過渡電阻換算到20℃時不高于3kΩ。 3、產品標準:MT818.5-1999。 4、MYP型電纜有3個帶絕緣屏蔽的主線芯和一個包覆半導電橡皮層的地線組成,圍繞半導電橡皮層墊芯絞合成纜。外面擠包黑色氯化聚乙烯橡皮護套或黑色氯丁橡皮護套。 5、導電線芯:采用軟銅線,其性能符合 GB/T3956-1997。 6、絕緣:采用GB7594.2-1987中XJ-00A型橡皮。 7、線芯識別:采用絕緣分色識別,主線芯紅、綠、白。 8、地線:采用半導電橡皮包覆。 9、絕緣屏蔽:在絕緣表面包半導電帶。 10、成纜:3個主線芯1個地線圍繞半導電橡皮墊芯按右向絞合成纜。 11、護套:采用GB7594.7-1987中XH-03A型橡皮。護套橡皮的氧指數≥40。 12、成品電纜的阻燃性能滿足MT386-1995的要求。 13、電纜標志:電纜表面印有型號、電壓、規格及制造廠名稱。 |
結構尺寸及主要技術參數Construction and main technical data ● 礦用移動屏蔽橡套軟電纜 Flexible shielding rubber-sheathed cables for mining purposes 型號(Type):UYP 額定電壓(Rating Voltage):380/660V
芯數截面 Nom.cross sectional areas mm2 |
導體結構 Conductor structure NO./mm |
絕緣厚度 Insulation thickness mm |
護套厚度 Sheath thickness mm |
電纜外徑 Average diameter |
參考重量 Cable approx. weight kg/km |
導體(銅)***大直流電阻 Max.D.C. resistance(20 ℃ ) Ω /km |
20 ℃載流量 Current carring capacity(20 ℃ ) A |
標稱 Normianal mm |
***大 Max mm |
| 3 × 4+1 × 4 |
56/0.30 |
1.4 |
3.5 |
23.7 |
27.2 |
730 |
4.950 |
35 |
| 56/0.30 |
4.950 |
| 3 × 6+1 × 6 |
84/0.30 |
1.4 |
3.5 |
26.4 |
30.1 |
959 |
3.300 |
46 |
| 84/0.30 |
3.300 |
| 3 × 10+1 × 10 |
84/0.40 |
1.6 |
4.0 |
30.9 |
34.7 |
1427 |
1.910 |
64 |
| 84/0.40 |
1.910 |
| 3 × 16+1 × 10 |
126/0.40 |
1.6 |
4.0 |
33.0 |
36.8 |
1675 |
1.210 |
85 |
| 84/0.40 |
1.910 |
| 3 × 25+1 × 16 |
196/0.40 |
1.8 |
4.5 |
39.0 |
43.2 |
2419 |
0.780 |
113 |
| 126/0.40 |
1.210 |
| 3 × 35+1 × 16 |
276/0.40 |
1.8 |
4.5 |
42.1 |
46.3 |
2952 |
0.554 |
138 |
| 126/0.40 |
1.210 |
| 3 × 50+1 × 16 |
396/0.40 |
2.0 |
5.0 |
47.1 |
51.4 |
3741 |
0.386 |
173 |
| 126/0.40 |
1.210 |
| 3 × 70+1 × 25 |
360/0.50 |
2.0 |
5.0 |
52.4 |
57.1 |
4790 |
0.272 |
215 |
| 196/0.40 |
0.780 | |
 |
備注: 1、電纜絕緣主線芯之間及主線芯與地線之間的絕緣電阻,換算到+20℃時不低于100MΩ·km。 2、主線芯屏蔽層的過渡電阻換算到20℃時不高于3kΩ。 3、產品標準:GB12972.5-1991。 4、UYP型電纜有3個帶絕緣屏蔽的主線芯和一個包覆半導電橡皮層的地線組成,圍繞半導電橡皮層墊芯絞合成纜。外面擠包黑色氯化聚乙烯橡皮護套或黑色氯丁橡皮護套。 5、導電線芯:采用軟銅線,其性能符合 GB/T3956-1997。 6、絕緣:采用GB7594.2-1987中XJ-00A型橡皮。 7、線芯識別:采用絕緣分色識別,主線芯紅、綠、白,地線黑色。 8、地線:采用半導電橡皮包覆。 9、絕緣屏蔽:在絕緣表面包覆半導電橡皮。 10、成纜:3個主線芯1個地線圍繞半導電橡皮墊芯按右向絞合成纜。 11、護套:采用GB7594.7-1987中XH-03A型橡皮。抗撕裂性能不低于7.5N/mm。 12、普通型UYP型成品電纜具有不延燃性能,阻燃型UYP型成品電纜的阻燃性能滿足MT386-1995的要求。 13、電纜標志:電纜表面印有型號、電壓、規格及制造廠名稱。 |
結構尺寸及主要技術參數Construction and main technical data ● 礦用移動屏蔽橡套軟電纜 Flexible shielding rubber-sheathed cables for mining purposes 型號(Type):UPQ 額定電壓(Rating Voltage):1140V
芯數截面 Nom.cross sectional areas mm2 |
導體結構 Conductor structure NO./mm |
絕緣厚度 Insulation thickness mm |
護套厚度 Sheath thickness mm |
電纜外徑 Average diameter |
參考重量 Cable approx. weight kg/km |
導體(銅)***大直流電阻 Max.D.C. resistance(20 ℃ ) Ω /km |
20 ℃載流量 Current carring capacity(20 ℃ ) A |
標稱 Normianal mm |
***大 Max mm |
| 3 × 10+1 × 10 |
84/0.40 |
1.8 |
4.5 |
31.7 |
34.9 |
1640 |
1.910 |
64 |
| 84/0.40 |
1.910 |
| 3 × 16+1 × 10 |
126/0.40 |
1.8 |
4.5 |
34.2 |
37.6 |
1899 |
1.210 |
85 |
| 84/0.40 |
1.910 |
| 3 × 25+1 × 16 |
196/0.40 |
2.0 |
5.0 |
40.3 |
44.3 |
2648 |
0.780 |
113 |
| 126/0.40 |
1.210 |
| 3 × 35+1 × 16 |
276/0.40 |
2.0 |
5.0 |
44.4 |
48.8 |
3201 |
0.554 |
138 |
| 126/0.40 |
1.210 |
| 3 × 50+1 × 16 |
396/0.40 |
2.2 |
5.5 |
51.5 |
54.6 |
4013 |
0.386 |
173 |
| 126/0.40 |
1.210 |
| 3 × 70+1 × 25 |
360/0.50 |
2.2 |
5.5 |
53.9 |
59.3 |
5079 |
0.272 |
215 |
| 196/0.40 |
0.780 |
| 3 × 95+1 × 25 |
475/0.50 |
2.4 |
6.0 |
62.1 |
68.1 |
6280 |
0.206 |
260 |
| 196/0.40 |
0.780 | |
 |
備注: 1、電纜絕緣主線芯之間及主線芯與地線之間的絕緣電阻,換算到+20℃時不低于100MΩ·km。 2、主線芯屏蔽層的過渡電阻換算到20℃時不高于3kΩ。 3、產品標準:Q/320282DCE037-2003。 4、UPQ型電纜有3個帶絕緣屏蔽的主線芯和一個包覆半導電橡皮層的地線組成,圍繞半導電橡皮層墊芯絞合成纜。外面擠包黃色氯化聚乙烯橡皮護套或黃色氯丁橡皮護套。 5、導電線芯:采用軟銅線,其性能符合 GB/T3956-1997。 6、絕緣:采用GB7594.2-1987中XJ-00A型橡皮。 7、線芯識別:采用絕緣分色識別,主線芯紅、綠、白。地線芯黑色。 8、地線:采用半導電橡皮包覆。 9、絕緣屏蔽:在絕緣表面包半導電帶。 10、成纜:3個主線芯和一個地線圍繞半導電橡皮墊芯按右向絞合成纜。 11、護套:采用GB7594.7-1987中XH-03A型橡皮。護套橡皮的氧指數≥40。抗撕裂性能不低于7.5N/mm。 12、成品電纜的阻燃性能滿足MT386-1995的要求。 13、電纜標志:電纜表面印有型號、電壓、規格及制造廠名稱。 |